Article
NPT vs NPTF: Same Size, Different Crests, Different Gauges
An NPTF thread measures the same as an NPT thread and screws into the same hole. The dry seal is made at the crests and roots, and only Dryseal gauges can prove it is there. What changes, what Class 1 and Class 2 ask for, and what to write on the drawing.
| Item | NPT, ASME B1.20.1 | NPTF, ASME B1.20.3 |
|---|---|---|
| Thread angle | 60° | 60° |
| Taper | 1 in 16 on the diameter | 1 in 16 on the diameter |
| Threads per inch, 1/8 to 1 | 27, 18, 18, 14, 14, 11.5 | The same |
| Basic diameters and hand-tight length | E0, E1, L1 from Table 2 of B1.20.1 | The same values |
| Crests and roots | 0.033p minimum, maximum in Table 1 of B1.20.1; not gauged on the part; the gap is filled by sealant | Roots truncated more than crests, within the limits of B1.20.3; metal-to-metal contact; inspected for Class 2 |
| Pressure-tight joint | Made up wrench-tight with a sealant | Designed to seal without sealant; a compatible lubricant or sealant may be used against galling |
| Gauges | L1 plug or ring | L1, plus an L2 ring (external) or L3 plug (internal); Class 2 adds a crest and root truncation check, usually 6-step gauges |
| Classes | None | Class 1, Class 2 |
I accept NPT threads with an L1 gauge.
Why do NPT and NPTF look and measure the same?
Because they come from the same thread. ASME describes Dryseal threads as "based on the USA (American) pipe thread". For 1/2-14 the published NPTF dimensions are the NPT values in Table 2 of ASME B1.20.1: a pipe outside diameter of 0.840 in (21.34 mm), a pitch diameter at the end of the pipe E0 of 0.75843 in (19.264 mm), a pitch diameter at the hand-tight plane E1 of 0.77843 in (19.772 mm), and a hand-tight engagement L1 of 0.320 in (8.13 mm). A caliper, a pitch gauge and an L1 gauge all see the same thread. The first article in this series covers how NPT differs from the 55° PT and PF threads.
Can NPT and NPTF be mixed?
They screw together, because the diameters, taper and pitch match. The differences are at the crests and roots, where an L1 gauge does not look. A common case is a valve with NPTF ports and only NPT fittings on the shelf. Whether that joint seals dry is a different question. The dry seal, explained in the next section, is designed for two Dryseal threads within specification. On a mixed joint, specify a sealant, or do not count on a dry seal.
Where does the dry seal come from?
From the crests and roots. ASME's description of Dryseal threads reads: "The roots of both the external and internal threads are truncated slightly more than the crests, i.e. roots have wider flats than crest, so that metal-to-metal contact occurs at the crests and roots coincident with or prior to flank contact." As the joint is wrenched tight, the wider root flat of one thread bears on the narrower crest of the other. ASME continues: "This sealing action at both the major and minor diameters tends to prevent spiral leakage."
NPT also limits truncation. ASME B1.20.1 sets a minimum of 0.033p, about 0.0024 in (0.06 mm) at 14 threads per inch, and a maximum in its Table 1. But those limits are met at the tool: when the threading tool is within them, the thread is accepted on in-process control, and the crest and root are not gauged on the part. The spiral gap between crest and root is expected, and the same standard says a pressure-tight NPT joint is "made up wrench-tight with a sealant". In NPTF the roots are truncated more than the crests on purpose, within the limits of ASME B1.20.3, so that the flats interfere, and for Class 2 that truncation is inspected on the finished thread. That is what a Dryseal tap or insert has to produce, and what a Dryseal gauge checks.
Does Dryseal mean no sealant at all?
No. ASME's description of the seal is conditional. It holds "provided that the mating threads are in accordance with standard specifications and tolerances and are not damaged by galling in assembly", and the same text says that where it does not interfere with the function, "the use of a compatible lubricant or sealant may be used to minimize the possibility of galling". Dryseal means the joint does not depend on the sealant. It does not forbid one. On stainless steel and other materials that gall, a lubricant at assembly is normal practice, and the drawing or purchase order should say whether one is allowed.
What do the extra gauges check?
An NPT thread is accepted with an L1 gauge alone, screwed on by hand, with the end of the thread landing within one turn of the gauge's notch or step. The first article in this series shows that gauge. An NPTF thread takes two checks, and a third for Class 2.
L1 plug or ring: the pitch diameter over the hand-tight length, within one turn, the same check as for NPT.
L2 ring for an external thread, L3 plug for an internal thread: the threads beyond the hand-tight length, the ones that engage when the joint is wrenched tight. The difference in turns between the L1 and the L2 or L3 gauge has to fall within half a turn of the basic difference. This is the check on taper over the working length.
6-step crest check and root check gauges, for Class 2: taper gauges whose steps show whether the crest and root truncation lie inside the limits.
An L1 gauge from an NPT set says nothing about the taper beyond the hand-tight length and nothing about truncation. A thread that passes it may or may not be an NPTF thread.
What is the difference between Class 1 and Class 2?
How much gets inspected, not how good the thread is. Gauge maker Thread Check quotes the standards. For Class 1, "Acceptability is determined by coordinated use of L-1 & L2 gages for external product threads and L-1 & L-3 gages for internal product threads", and crest and root truncation is "generally considered to be controlled by tooling or other means". For Class 2 the same gauging applies, "however, inspection of root and crest truncation is required", which in practice means the 6-step gauges or another method. A callout that says NPTF without a class leaves that choice to whoever reads it. Ask before the part is cut.
The other Dryseal threads, and two straight threads that are not Dryseal
| Thread | Form | Mates with | Note |
|---|---|---|---|
| NPTF | Taper; external and internal | NPTF | Type 1 |
| PTF-SAE SHORT | Taper; one thread shorter at the entering end | NPTF | For limited clearance or thin walls |
| NPSF | Straight; internal only | NPTF external | Dryseal straight thread |
| NPSI | Straight; internal only, slightly larger than NPSF | — | Dryseal straight thread |
ASME B1.20.3 also carries a table of recommended assembly limitations among these four Dryseal types; it is not reproduced here.
NPSF and NPSI are Dryseal threads. They are not the NPSM and NPSL straight pipe threads of ASME B1.20.1, which are for mechanical joints, not pressure-tight ones; those are in the second article in this series.
What should the drawing and the RFQ say?
Write the full designation and the class:
- The designation and the standard: 1/4-18 NPTF, ASME B1.20.3
- The class, written out: Class 1 or Class 2
- Whether a lubricant or sealant is allowed at assembly
- If the part is plated, whether the thread limits apply before or after plating
- Which gauges will accept the thread: L1 plus L2 or L3, and for Class 2 the crest and root check as well
Not "1/4 NPT or NPTF", not "1/4 pipe, dryseal". A supplier who inspects with NPT gauges only is inspecting an NPT thread.
This is general information, not engineering advice. Thread standards are revised; check the edition named on your drawing, and confirm gauging requirements with your own quality department.
Sean Shih is the founder of Celvor Industrial in Taichung, Taiwan.
If you are sourcing a turned part with pipe threads, send the drawing.